undefined
Guangdong Haibo Specialty Glass – Glass Solutions for Public Buildings
Haibo Glass Solutions for Public Buildings Project Manager: Mr. Wei, 13533794186 International Sales: Manager Cao, 13178822749
Sector positioning : Suitable for non‑commercial public buildings such as hospitals, schools, libraries, transportation hubs, and sports arenas, this product emphasizes public safety, durability and resistance to damage, fire‑code compliance, and ease of cleaning and maintenance. In high‑traffic areas, high‑security laminated glass is prioritized; in fire‑safety zones, fire‑resistant glass is mandatory. The solution fully complies with public‑building acceptance standards while balancing practical usability with long‑term operational and maintenance costs. 
1. Glass Solutions for General Fire‑Protection and Firefighting Scenarios (Non‑Commercial Public Buildings)
Core Positioning : Addressing the fire safety and firefighting needs of various public buildings, residential structures, and commercial ancillary facilities outside shopping malls, this solution focuses on key areas such as conventional fire compartments, evacuation routes, elevator lobbies, equipment rooms, shafts, and fire barriers, while strictly adhering to national fire safety codes and centering on… Fire‑resistance compliance, smoke and flame barrier, structural safety, emergency ventilation Four guiding principles for material selection eliminate the risks of rapid breakage and collapse, fire spread, and dense smoke dispersion that are common in ordinary glass under fire conditions.
1.1 Core Classification (National Standard Grading)
- A Classified as thermally insulated fire-resistant glass : Combines fire integrity and thermal insulation, with a specified fire-resistance rating. 0.5h-3.0h , suitable for evacuation stairwells, elevator lobbies, and main fire‑compartment partitions; a standard mandatory component of fire‑protection systems.
- C Non-insulated fire-resistant glass : Only fire integrity is required, with a specified fire-resistance duration. 0.5h-1.0h , compatible with smoke barriers, fire-rated curtain wall sections, and daylighting partitions for non-evacuation passageways.
1.2 Regional Selection and Contraindications
Required for evacuation routes and elevator lobbies. A Composite fire-resistant glass; optional for curtain wall fire compartments and smoke barriers. C Classified monolithic fire-resistant glass; ordinary glass is strictly prohibited from being used as a substitute for fire-resistant glass, on-site cutting is forbidden, and all accessories must be fire‑rated and compatible to ensure successful fire‑safety inspection and acceptance.
2. Standard Glass Selection for Common Areas
- Corridor / Staircase railing :10-12mm Double-tempered laminated glass—high safety, impact-resistant, and shatters without detaching.
- Public restroom / Shower room :8mm Tempered frosted glass—waterproof, moisture-resistant, privacy-protecting, and easy to clean.
Waiting for the bus / Waiting Hall Partition : Ultra-clear tempered laminated glass, offering unobstructed transparency and resistance to heavy pedestrian traffic.
Project Manager: Mr. Wei, 13533794186 Foreign Trade & Export: Manager Cao, 13178822749