Applications and Solutions for Anti-Slip Glass
Anti-slip glass is produced by applying processes such as acid etching, ceramic sintering, micro‑texturing, and anti‑slip coatings to a tempered or laminated glass substrate, creating a durable, wear‑resistant surface texture or anti‑slip layer. This significantly enhances the dry and wet friction coefficients, reducing the risk of slipping, while delivering superior safety performance. It balances safety, transparency, abrasion resistance, and easy cleaning, and can be combined with insulating glass, LOW‑E coatings, and other technologies to meet diverse anti‑slip requirements across multiple applications.
Scene 1: Indoor Dry Areas (Residential/Office/Showroom Floors, Stair Treads)
Scene 2: Indoor Wet Areas (Bathroom/Kitchen/Pool Changing Room, Shower Room Flooring)
Scene 3: Public Buildings/Commercial Spaces (Malls, Stations, Hospital Corridors, Elevator Cabins, Stage Floors)
Scene 4: Outdoor/Scenic Areas (Balcony/Terrace/Rooftop Garden, Scenic Trail/Viewing Platform, Ramp)
I. Core Overview and Key Parameters (Haibote Glass Standards)
1. Core Definitions and Processes
- Definition : Made with safety glass as the base material and featuring a non-slip surface treatment, it achieves “ Transparent + Non-slip + Safety ” Triple functionality.
- Mainstream process (Sorted by durability):
- Ceramic sintered anti-slip dots : High temperature ( 600–700℃ ) Fuse ceramic particles with glass, Mohs hardness ≥6 , never peels off, resistant to acids and alkalis, easy to clean, suitable for high‑traffic areas / Wet area.
- Acid-etched anti-slip : Chemical etching creates micron‑scale pits, resulting in a fine texture, excellent light transmission, and an integrated anti‑slip layer bonded to the glass—ideal for indoor use. / Low-traffic scenario.
- Micro-embossing / Sandblasting : Physical texture formation, low cost, moderate slip resistance, suitable for temporary use. / Low-requirement scenario.
- Non-slip coating : Coated with wear-resistant resin; quick to apply, available in custom colors, with moderate durability—suitable for light‑load indoor use.
2. Core Performance Metrics (Mandatory)
Indicator
|
Standard / Parameter
|
Explanation
|
Slip resistance rating ( DIN 51130 )
|
R9‑R13
|
R9 : Low-risk dry zone; R10 : Standard indoor; R11‑R13 : Wet area / Ramp / High risk
|
Coefficient of friction ( COF )
|
Dry state ≥0.6 ; wet state ≥0.5
|
Wet state ≥0.6 For high safety standards ( ASTM C1028 )
|
Base security
|
Tempered / Laminated
|
Tempered: Impact-resistant ≥30J ; Laminated: 1.14/1.52PVB/SGP , shatters without splattering, fall-resistant
|
Wear resistance
|
Taber Wear-resistant ≥500 Turn / No significant loss
|
Sintered type ≥1000 Turn, acid-etched type ≥600 Turn
|
Weather resistance
|
Temperature-resistant -20℃~120℃ ; UV 500h No discoloration
|
Outdoor use requires additional UV protection.
|
Thickness specification
|
6mm、8mm、10mm、12mm、15mm、19mm
|
Ground / Trailway priority ≥12mm Laminated
|
Maximum size
|
2440×3660mm
|
Can be spliced, single piece ≤2000×3000mm More secure
|
II. Application Scenarios + Landing Plan (including precise parameters)
Scene 1 : Indoor dry area (residential) / Office / Exhibition hall floor, stair treads)
1. Scene characteristics
Dry environment, moderate foot traffic, emphasis on openness and aesthetics; low risk of slipping, but basic slip resistance is required.
2. Deployment Plan (Parametric Configuration)
Project
|
Specific parameters
|
Reasons for Selection
|
Base glass
|
8mm/10mm Tempered white glass / Ultra-white glass
|
With sufficient strength and high transparency, ultra-clear glass elevates the sense of quality.
|
Anti-slip technology
|
Acid-etched anti-slip ( R10 Level)
|
Fine texture, does not impair light transmission, moderately priced, in dry form. COF≥0.65
|
Surface treatment
|
Semi-matte / Polished surface
|
Balances slip resistance with aesthetics and is easy to clean.
|
Slip resistance rating / Coefficient of friction
|
R10 ; dry state COF≥0.65 ; wet state COF≥0.55
|
Meets indoor dry-area safety standards
|
Fixing method
|
Dry hanging / Structural adhesive bonding (neutral silicone sealant)
|
Leave a gap 3–5 mm , base layer leveling (tolerance ≤2mm/m )
|
Applicable Scenarios
|
Living room flooring, office corridors, exhibition hall steps, indoor staircases
|
Aesthetics + Safety + Cost-effectiveness balanced
|
3. Installation and Acceptance
- Substrate: cement screed, moisture content ≤8% , no hollow sounds.
- Installation: Transport the glass in a vertical position, use vacuum suction cups, and ensure uniform joint gaps. 2–3 mm ).
- Acceptance criteria: The surface shall be free of scratches, with uniform anti-slip texture, and provide slip resistance when walked on in a dry condition.
Scene 2 : Indoor wet area (bathroom / Kitchen / Pool changing rooms, shower room floors)
1. Scene characteristics
Long-term dampness and water stains / Oil stains, walking barefoot, and a high risk of slipping—require Anti-slip in high-humidity conditions + Waterproof + Easy to clean 。
2. Deployment Plan (Parametric Configuration)
Project
|
Specific parameters
|
Reasons for Selection
|
Base glass
|
10mm/12mm Tempered +1.52PVB Laminated
|
Laminated to prevent breakage and falling, with a thickness that ensures load-bearing capacity.
|
Anti-slip technology
|
Ceramic sintered anti-slip dots ( R11 Level)
|
Wet state COF≥0.6 , water- and stain-resistant, never peels off, Mohs hardness 6+
|
Non-slip dot specifications
|
Diameter 2–3 mm , spacing 8–10 mm , coverage rate 25%‑30%
|
Non-slip and comfortable underfoot, with no water pooling.
|
Surface treatment
|
Matte finish + Antifouling coating
|
Water-resistant, easy to clean, and oil-stain resistant. / Detergent corrosion
|
Slip resistance rating / Coefficient of friction
|
R11 ; dry state COF≥0.7 ; wet state COF≥0.6
|
Meets barefoot safety requirements in wet areas ( DIN 51097 B/C Level)
|
Waterproof seal
|
Neutral weather-resistant sealant (warranty) 10 year) + Waterproof underlayment
|
Seams are fully filled with no air bubbles to prevent water leakage.
|
Applicable Scenarios
|
Shower room floor, kitchen work area, pool changing room, and wet/dry separation zone in the bathroom
|
Optimal slip resistance when wet, durable and easy to maintain.
|
3. Installation and Acceptance
- Base layer: Apply waterproofing ( JS/ Polyurethane), water-tightness test ≥24h No leakage.
- Installation: Place rubber pads under the glass base to prevent direct contact; ensure proper drainage slope. ≥1%。
- Acceptance criteria: No slipping when walking on a wet surface, no water leakage at the seals, and no delamination of the anti-slip dots.
Scene 3 Public building / Commercial space (shopping mall) / Station / Hospital corridors, elevator cabs, stage floors)
1. Scene characteristics
High pedestrian traffic, frequent foot traffic, requires High wear resistance + High anti-slip + Easy to clean + Security Transparency , Public safety requirements are stringent.
2. Deployment Plan (Parametric Configuration)
Project
|
Specific parameters
|
Reasons for Selection
|
Base glass
|
12mm/15mm Tempered +1.52PVB Laminated
|
High strength and impact-resistant; laminated to prevent injury from shattered fragments.
|
Anti-slip technology
|
Ceramic sintered non-slip ( R11‑R12 Level)
|
Wear-resistant ≥1000 Turn, wet state COF≥0.6 , suitable for high foot traffic
|
Non-slip texture
|
Grid / Cross pattern / Dense points, coverage rate 30%–40%
|
Non-slip and evenly distributed, with stable load-bearing performance and no dirt accumulation.
|
Surface treatment
|
Fingerprint-resistant + Antifouling coating
|
Reduces stain residue and makes everyday cleaning convenient.
|
Slip resistance rating / Coefficient of friction
|
R12 ; dry state COF≥0.75 ; wet state COF≥0.65
|
Meets the highest safety standards for public areas.
|
Fixing method
|
Point-supported pendant (stainless steel) Φ10mm ) + Structural adhesive
|
Spacing ≤600mm , load-bearing ≥ Glass weight 2 times
|
Applicable Scenarios
|
Shopping mall corridors, station concourses, hospital hallways, elevator cabs, stage floors
|
Safety + Wear-resistant + Transparent and compliant with public standards.
|
3. Installation and Acceptance
- Base layer: Steel structure / Concrete substrate, flatness tolerance ≤1.5mm/m 。
- Installation: The pendant is precisely positioned (tolerance ≤1mm ), the glass is evenly stressed and shows no shaking.
- Acceptance: No wear or degradation under high-frequency stepping; slip resistance remains stable in wet conditions; permeability meets design specifications.
Scene 4 : Outdoor / Landscape (balcony / Terrace / Rooftop gardens, scenic boardwalks / Viewing platform, ramp)
1. Scene characteristics
Open-air environment, rainwater / Frosting / Snow accumulation, large temperature differences, required High weather resistance + Anti-slip in high-humidity conditions + Structural Safety + Fall protection 。
2. Deployment Plan (Parametric Configuration)
Project
|
Specific parameters
|
Reasons for Selection
|
Base glass
|
15mm/19mm Tempered +2.28SGP Laminated (three-layer: 8+1.52PVB+8 )
|
SGP Intensity is PVB 5 times, impact-resistant / Fall protection, compatible with boardwalks / Platform
|
Anti-slip technology
|
Micro-embossing + Ceramic sintering composite ( R12‑R13 Level)
|
Wet state COF≥0.7 , highly weather-resistant and suitable for rainwater / Frosty environment
|
Non-slip texture
|
Depth 0.3‑0.5mm Embossing + Sintering point, coverage rate 40%–50%
|
Maintains high friction even in extremely slippery conditions.
|
Surface treatment
|
Ultra-weather-resistant UV-protection coating
|
Resistance UV , rain, temperature differences, lifespan ≥15 year
|
Slip resistance rating / Coefficient of friction
|
R13 ; dry state COF≥0.8 ; wet state COF≥0.7
|
Meets the highest outdoor slip-resistance standards, suitable for ramps. / Boardwalk
|
Structural Safety
|
Resilience ≥1000kg/ ㎡; wind resistance ≥12 Level; Fall Protection
|
Compliant with GB/T 38784‑2020 Curtain Wall Glass Standards
|
Fixing method
|
Steel structural frame + Back bolt + Sealant
|
Frame rust protection (hot-dip galvanizing) / Stainless steel), spacing ≤500mm
|
Applicable Scenarios
|
Scenic area glass walkways, viewing platforms, outdoor ramps, rooftop gardens, and balcony floors
|
Safe and durable in extreme environments, with a clear, unobstructed view.
|
3. Installation and Acceptance
- Base layer: anti-corrosion treatment for steel structures, load-bearing capacity ≥ Design value 1.5 Times.
- Installation: Glass Joint Seams ≤3mm , Weather-resistant sealant (warranty) 15 Year), drainage is smooth.
- Acceptance: Wet State / The frost‑free condition ensures safe operation, with no structural deformation and no seal aging.
III. General Construction and Acceptance Standards
1. Standard Construction Process
- Detailed design (confirmation of slip resistance class, fabrication process, dimensions, and load requirements) →
- Substrate preparation (leveling) / Waterproof / Steel structure) →
- Glass processing (tempering) / Laminated + Anti-slip treatment) →
- On-site measurement verification (error) ≤1mm ) →
- Glass handling (vertical placement, foam protection, vacuum suction cups) →
- Installation and Fixing (Pendant) / Structural adhesive, with evenly spaced joints) →
- Sealing and caulking (weather-resistant sealant, fully filled with no air bubbles) →
- Cleaning and Maintenance →
- Acceptance (Anti-slip) + Safety + Appearance + Function)
2. Critical Control Point
- Processing Sintering temperature 600–700℃ , to prevent glass deformation; laminated PVB/SGP Bubble-free, adhesive strength ≥1.5 N/mm² 。
- Installation : The substrate must be smooth and level, with moisture content meeting the specified requirements; glass shall not come into direct contact with metal—use elastic shims; sealant must be neutral and covered by a warranty. ≥10 Year.
- Transportation : Store vertically, protect against impacts and scratches; do not lay flat or stack.
3. Haibote Glass Service Support
- Free detailed design, drawing production, and material estimation; custom slip-resistance grading. / Texture / Size.
- Provide Tempered / Laminated Safety Inspection Report.
- On-site technical guidance and standardized installation to ensure successful implementation of the plan.
- After-sales warranty: Sintered type 15 Year, acid-etched type 10 Year, coated type 5 In the year, quality issues will be handled free of charge.
IV. List of Common Standard Configurations
- 8mm Tempered + Acid-etched anti-slip ( R10 ) : Indoor dry area floor / Stairs, dry condition COF≥0.65 , great value for money.
- 10mm+1.52PVB Laminated + Ceramic sintering ( R11 ) : Bathroom / Kitchen wet area, wet condition COF≥0.6 , safe and durable.
- 12mm+1.52PVB Laminated + Ceramic sintering ( R12 ) : Shopping mall / Station public walkways, wear-resistant ≥1000 Turn, high-traffic adaptation.
- 15mm+2.28SGP Laminated + Composite anti-slip ( R13 ) Scenic area boardwalk / Outdoor platform, wet condition COF≥0.7 , fall protection / Weather-resistant.